ASP-146-PA-3-for-Intercom.zip.

This archive contains the files necessary to use the Bendix PA-3 plotter
with Intercom 1000-DP. It contains a modified version of Intercom 1000-
DP that has a small change needed by the PA-3 interface subroutine, a
modified Intercom subroutine Appendix 1 with the PA-3 interface
subroutine, and a small test program that illustrates use of the
interface.

For details, see the Application Section Project 146 document:

    https://rbk.delosent.com/allq/Q8764.pdf

Contents:

ASP 146-1.pti
    PA-3 machine-language interface subroutine for use
    with the Intercom 1000-DP Appendix 1 subroutine library. This can be
    appended to the
    standard Appendix 1 tape image as block 12. It is stored on line 17
    and runs out of line 19.

ASP 146-2.pti
    PA-3 machine-language interface subroutine for use
    with the Intercom 1000-DP Appendix 2 subroutine library as block 7.
    It is stored on
    line 17 and runs out of line 05.

Int-1000D-App-I-PA-3.pti
    Intercom 1000-DP Appendix 1 with the PA-3 interface subroutine
    appended as block 12. After loading the Int-1000D-PA3.pti tape image
    below and Intercom running in manual mode, do the following.

      * Halt the G-15.
      * Unload the Intercom tape image from the reader.
      * Enter ENABLE-s on the typewriter to cancel the TYPE IN command
        currently in progress.
      * Load this file in the tape reader.
      * Enter ENABLE-p on the typewriter to load the first block.
      * Set the COMPUTE switch to GO. The bell will ring and the Input-
        Output register will show a TYPE IN command (lamps 01100).
      * On the typewriter, enter "121700-" followed by tab and "s". The
        tape will advance until the subroutine is loaded. After that,
        Intercom will return to manual mode and the bell will ring.
      * See the Intercom 1000 manual on page 14 if you need to load
        other subroutines in addition to this one:
        https://bitsavers.org/pdf/bendix/g-15/
                APG-07581-4_Intercom1000_Pgm_Man_Apr61.pdf.

Int-1000D-PA3.pti
    Intercom 1000-DP tape image with the modification necessary to
    support the PA-3 plotter subroutine. This version can also be used
    for ordinary Intercom operations without the plotter.

Intercom-PA-3-Test.pti
    Loadable Intercom 1000-DP program that draws a simple graphic on the
    plotter. Load this image into Intercom channel 9 with the command
    "550900". Execute the program with the command "690900". On the
    retro-g15 emulator, position the pen at least 400 steps to the right
    of the plotter's home position on the left margin.

Intercom-PA-3-Test.txt
    Script for the simple plotter test program. This can be keyed in
    manually, or on the retro-g15 emulator it can be entered using
    the typewriter's Type-O-Matic feature. It is stored on channel 9 and
    can be run with a "690900" command.

Paul Kimpel